The ProSoft MVI69E-MBTCP is an enhanced communication module designed to provide seamless Modbus TCP/IP connectivity for CompactLogix® systems. It allows industrial automation controllers to interface efficiently with Modbus TCP/IP networks, enabling data exchange between disparate systems. The module supports multiple client and server connections, ensuring flexibility in different applications. It also provides diagnostic tools and LED indicators for quick troubleshooting, making it a reliable solution for demanding industrial environments.
General Info
-
Manufacturer: ProSoft Technology, Inc.
-
Model Number: MVI69E-MBTCP
-
Type: Modbus TCP/IP Communication Module
-
Number of Channels: Supports multiple client and server connections
-
Output Signal Type: Digital output (converted from Modbus TCP/IP data)
-
Compatibility: Compatible with Rockwell Automation CompactLogix® processors (firmware version 10 or higher)
-
Weight: Not specified in the current document
Features
-
Seamless Modbus TCP/IP Integration: The MVI69E-MBTCP module integrates Modbus TCP/IP networks with CompactLogix® controllers, providing seamless communication with up to 20 client connections and multiple server connections. This integration capability makes it ideal for large-scale industrial automation systems requiring consistent data exchange.
-
High Data Capacity: With support for up to 10,000 data words and configurable floating point data movement, this module ensures extensive data storage and processing, making it suitable for applications requiring large amounts of data handling.
-
Enhanced Diagnostics: The module includes diagnostic LEDs and ProSoft Discovery Service (PDS) tools, allowing operators to quickly identify and resolve communication issues. This feature ensures minimal downtime and effective system monitoring.
-
Robust Environmental Specifications: Designed to operate within a temperature range of 0°C to 60°C and withstand up to 95% relative humidity, the module is built for harsh industrial environments, ensuring consistent and reliable performance.
General Specifications
- Compatibility: Compatible with Rockwell Automation CompactLogix® processors (firmware version 10 or higher)
- Power Supply Distance Rating: 4 (installation on the first 2 slots of the 1769 bus)
- Current Load: 500 mA @ 5 VDC
- Operating Temperature: 0°C to 60°C (32°F to 140°F)
- Storage Temperature: -40°C to 85°C (-40°F to 185°F)
- Relative Humidity: 5% to 95%, non-condensing
- Supported Operating Systems: Windows® 10, 8, 7, Vista, XP Professional (Service Pack 1 or 2)
- RAM Requirements: 128 MB minimum, 256 MB recommended
- Dimensions: Standard 1769 Single-slot module
- Debug/Application Port: 10/100 Mbps Ethernet Port (Auto-negotiating)
Communication Interfaces
- Ethernet Port: 10/100 Mbps, RJ45 connector with auto crossover detection
- Modbus Function Codes Supported: 1 (Read Coil Status), 2 (Read Input Status), 3 (Read Holding Registers), 4 (Read Input Registers), 5 (Force/Write Single Coil), 6 (Preset/Write Single Holding Register), 8 (Diagnostics - Slave Only), 15 (Force/Write Multiple Coils), 16 (Preset/Write Multiple Holding Registers), 17 (Report Slave ID - Slave Only), 22 (Mask Write Holding Register - Slave Only), 23 (Read/Write Holding Registers - Slave Only)
Modbus Client
- Client Connections: 20
- Command List: Up to 16 commands per client connection, configurable for function, slave address, register addressing, and word/bit count
- Command Control: Configured commands can be controlled directly from ladder logic
- Polling of Command List: Configurable polling, including continuous and on change of data
- Status Data: Error codes available for each command; maintains a slave status list for active Modbus clients
Modbus Server
- Server Connections: 10 MBAP Connections, 10 Encapsulated Modbus Connections
- Status Data: Error codes, counters, and port status available for each configured slave
Memory Specifications
- Available Data Memory: Up to 10,000 words
- Floating Point Data Support: Supports floating point data movement, including configurable support for Enron, Daniel®, and other implementations
Technical Specifications
Electrical Specifications
- Input Power Requirement: 500 mA @ 5 VDC
- Power Supply Distance Rating: 4 (installation on the first 2 slots of the 1769 bus)
Environmental Specifications
- Operating Temperature: 0°C to 60°C (32°F to 140°F)
- Storage Temperature: -40°C to 85°C (-40°F to 185°F)
- Relative Humidity: 5% to 95%, non-condensing
Communication Interfaces
-
Ethernet Port:
- Speed: 10/100 Mbps
- Connector: RJ45 with auto crossover detection
Modbus Function Codes Supported
-
Supported Function Codes:
- 1 (Read Coil Status)
- 2 (Read Input Status)
- 3 (Read Holding Registers)
- 4 (Read Input Registers)
- 5 (Force/Write Single Coil)
- 6 (Preset/Write Single Holding Register)
- 8 (Diagnostics - Slave Only)
- 15 (Force/Write Multiple Coils)
- 16 (Preset/Write Multiple Holding Registers)
- 17 (Report Slave ID - Slave Only)
- 22 (Mask Write Holding Register - Slave Only)
- 23 (Read/Write Holding Registers - Slave Only)
Modbus Client
- Client Connections: 20
- Command List: Up to 16 commands per client connection, configurable for function, slave address, register addressing, and word/bit count
- Command Control: Configured commands can be controlled directly from ladder logic
- Polling of Command List: Configurable polling, including continuous and on change of data
- Status Data: Error codes available for each command; maintains a slave status list for active Modbus clients
Modbus Server
- Server Connections: 10 MBAP Connections, 10 Encapsulated Modbus Connections
- Status Data: Error codes, counters, and port status available for each configured slave
Memory Specifications
- Available Data Memory: Up to 10,000 words
- Floating Point Data Support: Supports floating point data movement, including configurable support for Enron, Daniel®, and other implementations
LED Indicators
- Configuration Status
- Application Status
- Backplane Connectivity Status
- Module Status
At Axiom, we specialize in providing high-quality spare parts for Distributed Control Systems (DCS) and Programmable Logic Controllers (PLC). Our comprehensive product portfolio includes parts from approximately 20 leading brands, such as ABB, Bently Nevada, Honeywell, GE, Yokogawa, Allen Bradley, Foxboro, Ovation, Hima, Emerson, Triconex, Woodward, ICS Triplex, Bachmann, and Schneider. This focused expertise allows us to offer in-depth solutions in the automation sector, setting us apart from many competitors and ensuring we deliver the most advanced and reliable products to our clients.
Contact Information
- Email: sales@axiomplc.com
- TEL: +86 191 2948 1391
No FAQs found. Please verify your request search.
Frequently Asked Questions
Is our price competitive?
What is the warranty period?
What payment methods do we accept?
What shipping methods do we use?
What is our delivery time?
How do we package the goods?
How can customers contact us and request a quote?
-
Vendor: GE
GE Fanuc IC752SPL011-BA Operator Interface Panel
Sale price $150.00Regular price $280.00 -
Vendor: GE
General Electric IC755SUE10CTD Touch Panel
Sale price $150.00Regular price $280.00 -
Vendor: GE
GE Multilin 760-P5-G5-D5-HI-A1-R Feeder Protection Relay
Sale price $130.00Regular price $230.00 -
Vendor: GE
GE WESDAC D20ME Substation Controller
Sale price $120.00Regular price $220.00